I run a cold plunge repair company. We logged 722 faults since May — here's what actually breaks

Full disclosure: I own The Cold Standard, a cold plunge service company. Our techs tag every fault they find into a database, and I thought this sub would find the patterns useful:

•    The circulation pump is the #1 failure (17.7% of all faults) and causes 40% of "unit completely dead" calls.
•    Almost half of all problems are in the water path (pumps, filters, plumbing, valves): 48.8%. Many "my chiller is broken" calls turn out to be a clogged filter starving the pump.
•    Chillers fail less than people think. Compressor or whole-chiller failures were only 7.2%.
•    31.6% were preventable, and where we could identify a cause, skipped maintenance was #1.
•    Filter cartridges: 86% of filter cartridge faults were preventable.
•    Commercial units were more often preventable than home units (45% vs 31%).

Repeat offenders we see:
•    extension cords and power strips
•    pool chlorine tablets in a plunge
•    not pre-filling the filter housing (causes airlocks)
•    hard-water scale
•    biofilm in the lines

Full breakdown and methodology (no customer info): coldstandardservice.com/cold-plunge-failure-report

Happy to answer questions about any brand or error code.