u/brurtle

Image 1 — Powerwall 2 energy flow trends not recording
Image 2 — Powerwall 2 energy flow trends not recording
Image 3 — Powerwall 2 energy flow trends not recording
Image 4 — Powerwall 2 energy flow trends not recording

Powerwall 2 energy flow trends not recording

I am having an issue with my Powerwall 2 energy trends. Last week the electricians were working on my main switchboard and the Solar CT clamp (neurio transmitter) was turned off so I lost solar readings. Yesterday they came out and turned it back on (it is behind the board) and my instantaneous readings returned (the main page on the app).

However, when I click for the trends for solar nothing comes up, and the home load trend is also incorrect. The home load trends seems to be the net difference between actual home load and the solar if that number is positive.

My home assistant readings which come from a tesla custom integration also seem to be reporting solar as actual solar plus battery charge rate, and load as the net actual solar minus actual load with a 0 minimum.

I have uninstalled/reinstalled the app on my phone, reset the gateway, and done a full restart of the system.

Hoping somebody has some advice so I can direct the electricians. My gut feeling is that it is related to the CTs and the connections to the neurio transmitter and gateway but open to any troubleshooting suggestions.

Thank you

u/brurtle — 3 days ago