u/Legitimate-Feature42

Just bought a Double Eagle MK18 MWS – what should I change first?

Hey guys,

I ended up buying a Double Eagle MK18 MWS and now I’d like some advice on what beginner upgrades or changes you would recommend doing first.

For those of you who have experience with this platform, what would you change right away and what would you leave stock for now?

I’m especially interested in:
- hop-up bucking recommendations
- whether the hop unit should be changed or left stock at first
- if there are any common weak points I should address early
- whether I should change things like the nozzle / nozzle spring / inner barrel
- any other small upgrades or reliability mods you think are worth doing from the start

My main goals are:
- good reliability
- good accuracy and consistency
- solid performance in games
- keeping it beginner friendly without replacing things that don’t really need to be changed yet

Thanks.

reddit.com
u/Legitimate-Feature42 — 4 days ago

Schneider EBO 3.2.3 AS-P – Browser script errors + “Server version not compatible with client”

Hi everyone, I could really use some help with an older Schneider EcoStruxure Building Operation system that I recently had to take over.

The system is:

Schneider EcoStruxure Building Operation
AS-P controller
Server version: 3.2.3

This BMS was originally built a few years ago by a colleague who no longer works with us anymore, and unfortunately we can’t get in touch with him. I recently inherited this project and I’m now trying to get everything working properly again.
Until about a year ago, technicians and the customer were able to access the BMS normally through the browser and everything apparently worked fine.
Now however, the graphics continuously throw popup script errors in the browser and some elements no longer work correctly.

The errors I get are things like:

MutationEvent is not defined
Script error in SignalChangeEvent (Bind_Real_Value)
Text_ValueText_NumericPresentationScript

I tried:

Chrome
Edge
Firefox ESR
Internet Explorer mode
and I still get the same issues.

I also tried connecting using EBO WorkStation, but I get:

Server version not compatible with client

The AS-P is running version 3.2.3, while the EBO version installed on my laptop is newer.

I’ll attach screenshots with:

the browser popup errors
the WorkStation compatibility/version error

My questions are:

  1. Do I need an older EBO version in order to connect to these controllers?
  2. Is there still any way to obtain older EBO 3.2.x installation kits?
  3. Has anyone dealt with these browser popup/script issues before?
  4. Is there any recommended browser or workaround that still works reliably with these older systems?
  5. What would you recommend doing next in this situation?

Any help or ideas would be greatly appreciated because at the moment I honestly don’t know what else to try.

u/Legitimate-Feature42 — 15 days ago