Pentair Plus30 SWGs are all DEFECTIVE!
I installed a 10k gal, plaster, salt water pool last summer using all top-of-the-line Pentair equipment: Intellichlor Plus30 SWG, two Intelliflow VSPs (one for pool, one for water features), and a cartridge filter. I have a pool guy, but notice the chemicals are never right when I occasionally test with near-zero chlorine and skyhigh pH (due to new plaster, of course). I then take the plunge and join the Trouble Free Pool cult (praise be to Taylor Test Kit) to find out what's really going on. After countless hours, I confidently determine the Plus30 SWG isn't generating any chlorine via overnight chlorine lost tests followed by overnight chlorine gain tests. I'm running that thing at 75% for 21 hours a day and should be generating over 10ppm daily. Instead, it generates NOTHING.
I have now had THREE Plus30 SWGs installed by Pentair. Not a single one has ever generated a single ppm of chlorine. I'm so frustrated with Pentair. It's clear they've had a bad batch of Plus30's but instead of throwing them out, they're installing and hoping pool owners are too stupid to notice. I want to shove my foot up the a** of their dipsh*t CEO.
Has anyone else had issues with their Plus30/40/50/60 SWGs?