Is this good? N 4 M
I have just replaced the x belt.

I have just replaced the x belt.
I have a new Neptune 4 max and i was calibrating it via the tests from orca slicer. I did the flow ratio and the pressure tests and i changed the config file accordingly.
​
Then i tried the temp file and the test string came out like the one below because for some reason the nozzle was trying to pring 1 mm or so higher. So i stopped it and tried resetting the settings on orca and same result. But when I print the same file from the printers display it works normally.
​
Can anyone help?
​
I was changing the z offset on orcasilcer because it was too high until in reached - 2.37 and it printed but something is wrong with the first layer.
After this print i tried to print something bigger and I reduced it to - 2.3756 but it didn't print the first layer well and I got a big blob of plastic on the nozzle and it also ate a little of the bed too.
Settings:
Elegoo neptune 4 max
Orcaslicer
Rapid PLA+ sample in that came with the box
Nozzle 0.4mm (first layer 210C) 205C bed 60C
Speed: first 50mm/s, outer wall 120 mm/s, inner wall 160 mm/s, first infill 80mm/s
Retraction 0.7mm
I was adjusting the z axis on orcasilcer because I was printing the retraction test and it was too high (last Pic) . I went to the leveling setting on the printer and I thought I had to put that in the orca slicer (it was - 2.360).
I tried to print it and the test lines on the edge printed ok so I just left it. When I came to check on it this is what I saw.
What can I do about it?
😭😭 Printer model Elegoo Neptune 4 max
Hi guys,
I just go this neptune 4max yesterday and I printed benchy but it was a little stringy so I wanted to level it aga but not the nozzle head keeps pushing and bending the bed and the bed also appears to not be positioni g correctly. Any is help appreciated
Hey everyone,
I bulit my first printer yesterday and printed a benchy and it was stringy (the printer was on a table and the table was shaking I don't know if that is what made it stringy). Today I tried printing the retraction test on orcaslicer and the first time it didn't stick to the bed. I tried again and this what I got before I started sliding again. Can I get some help?
Settings:
Elegoo neptune 4 max
Orcaslicer
Rapid PLA+ sample in that came with the box
Nozzle 0.4mm (first layer 210C) 205C bed 60C
Speed: first 60mm/s, outer wall 120 mm/s, inner wall 160 mm/s, first infill 80mm/s
Retraction 0.7mm
Hey guys,
I live in Germany and I have just received my heltec v4 with an upgraded 20cm antenna and after one day I started finding nodes but my messages aren't getting through even though I can see them messaging each other.
What could be the issue?
Hi,
I got this camera from my grandfather and it worked fine for about 2 or 3 winds then when i tried to wind it again, the lever just goes half way and gets stuck. I also believe that I have the Pad Of Death problem but I don't think I is related to this.
I have noticed that there is a gear stopper that doesn't let the lever go back and when I manually reset it, I goes back.
I would appreciate some help with this so I can show my grandfather some pics using his camera.
Thanks